YB series substation is a kind of compact power distribution device that integrates medium voltage electrical equipment, transformer, and low voltage electrical equipment. It can be used in high-rise buildings, building in urban and rural areas, residential communities, high-tech development areas, small and medium-size factories. mining areas, oil fields, temporary construction sites, and other premises. It also can be used for acceptance and distribution of power in the power distribution systems of 6-15KV, 50HZ (60HZ), ring main power distribution system, and double power supply or radiate terminal power distribution system.

Operating Conditions


1. Altitude:  1000m;

2. Ambient temperature: -25℃ ~+40℃;

3. Relative humidity: Daily average not exceeding 95%,Monthly average not exceeding 90%;

4. Installation location: A location free from fire, explosion hazards, conductive dust, chemical corrosive gases, and severe vibrations;

When the above normal use conditions are exceeded, the user can negotiate with the company.

 

Model and meaning


YB-model

 

Technical Specification


Prefabricated Substation Parameter
Item Unit Parameter
MV Unit Rated frequency Hz 50
Rated Voltage V 7.2 12
Rated Current A 400、630
Transfer current A 1200-3150
Power Frequency Withstand Voltage (to ground/isolation break) KV 42/48
Lightning Impulse Withstand Voltage (ground/isolation fracture) KV 75/85
Rated Short-Circuit Breaking Current(injection fuse) KA 31.5
Rated Capacity kVA 30-2000
Tapping Range ±2×2.5%,±5%
Transformer Unit Connection Group Yyn0、Dyn11
Impedance Voltage % 4、4.5
LV Unit Rated Voltage V 220、380
Main Bus Rated Current A 50-4000
Branch Current A 5-800
Shell Protection Level(Standard) IP33D
Noise Level dB ≤50
Load Switch Parameter
Item Unit Parameters
FKN12-12 Load Switch FZN25-12 Vacuum Load Switch
Rated Voltage kV 12
Rated Frequency Hz 50
Rated Current A 630/125
Rated Breaking Load Current 630
Thermal Withstand Current kA/s 20/2 20/4
Dynamic Withstand Current kA 50
Rated Short-circuit Making Current(Peak) 50
Full Load Breaking Times Times 100
Mechanical Life 3000 5000
Rated Short-circuit Breaking Current
(phase to phase and to ground)/break
kV 42/48
Lightning Impulse Voltage (phase to phase and to ground)/break 75/85

 

Medium Voltage Fuse Parameters
Model Rated Voltage(kV) Breaking Current(A) Rated Current(kA) Fuse Rated Current(A)
UK Model Chinese Model
SDL※J XRNT-12 12 40 31.5 6.3/10/16/20/25/31.5/40
100 50/63/70/80/100
125 125

 

Low Voltage Circuit Breaker Parameters
Model Type of Release Rated Current of Release(A) Switching Capacity (kA/AC380V)
DW15-630 Thermal-magnetic 315/400/630 40
DW15-1000 630/800/1000 50
DW15-1600 1600
DW15-2500 1600/2000/2500 60
CW1-2000 Intelligent 630/800/1000/1250/1600/2000 65(80)
CW1-3200 2000/2500/3200

If you need more detailed information, please view the pdf document above or contact us.